Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters

Database
Language
Document Type
Year range
1.
GMS Hyg Infect Control ; 15: Doc16, 2020.
Article in English | MEDLINE | ID: covidwho-690579

ABSTRACT

Background: Healthcare workers and large parts of the population are currently using personal protective equipment, such as face masks, to avoid infections with the novel coronavirus SARS-CoV-2. This equipment must be sterilized as gently as possible before reuse. One possibility is thermal inactivation, but professional autoclaves with their high temperatures are often not available or suitable. If the inactivation period is long enough, coronavirus inactivation can also be carried out at relatively low temperatures. The required duration was determined in this study. Material and methods: Data from published thermal inactivation studies on coronaviruses were applied to determine the temperature dependence of the rate constant k(T) for each coronavirus by employing Arrhenius models. Results: The data obtained exhibit large variations, which appear to be at least partially caused by different sample properties. Samples with high protein content or samples in dry air sometimes seem to be more difficult to inactivate. Apart from this, the Arrhenius models describe the thermal inactivation properties well and SARS-CoV and SARS-CoV-2 can even be represented by a combined model. Furthermore, the available data suggest that all samples, including critical ones, can be mathematically included by a worst-case Arrhenius model. Conclusion: Coronaviruses can already be inactivated at relatively low temperatures. For most samples, application times of approximately 32.5, 3.7, and 0.5 minutes will be sufficient at 60°C, 80°C, and 100°C, respectively, for a 5 log-reduction. For difficult conditions, the worst-case model provides significantly longer application times of 490, 55, and 8 minutes for the temperatures mentioned.

2.
GMS Hyg Infect Control ; 15: Doc08, 2020.
Article in English | MEDLINE | ID: covidwho-599539

ABSTRACT

Background: To slow the increasing global spread of the SARS-CoV-2 virus, appropriate disinfection techniques are required. Ultraviolet radiation (UV) has a well-known antiviral effect, but measurements on the radiation dose necessary to inactivate SARS-CoV-2 have not been published so far. Methods: Coronavirus inactivation experiments with ultraviolet light performed in the past were evaluated to determine the UV radiation dose required for a 90% virus reduction. This analysis is based on the fact that all coronaviruses have a similar structure and similar RNA strand length. Results: The available data reveals large variations, which are apparently not caused by the coronaviruses but by the experimental conditions selected. If these are excluded as far as possible, it appears that coronaviruses are very UV sensitive. The upper limit determined for the log-reduction dose (90% reduction) is approximately 10.6 mJ/cm2 (median), while the true value is probably only 3.7 mJ/cm2 (median). Conclusion: Since coronaviruses do not differ structurally to any great exent, the SARS-CoV-2 virus - as well as possible future mutations - will very likely be highly UV sensitive, so that common UV disinfection procedures will inactivate the new SARS-CoV-2 virus without any further modification.

SELECTION OF CITATIONS
SEARCH DETAIL